University of Virginia Library

Search this document 
  
  
  
  
  
  
  
  
collapse section 
  
  
  
collapse section 
  
  

collapse sectionONE. 
  
  
  
collapse section 
  
collapse section 
  
  
  
collapse section 
  
  
  
  
  
  
  
  
  
  
collapse sectionTWO. 
collapse section 
  
  
  
  
  
  
  
collapse section 
collapse section 
collapse sectionA. 
  
  
  
  
  
collapse sectionB. 
  
  
  
  
  
  
collapse section 
 I. 
collapse sectionII. 
  
  
  
  
  
  
collapse section 
  
  
  
  
  
collapse section 
 I. 
collapse sectionII. 
collapse section 
 A. 
 B. 
 C. 
 D. 
 E. 
 F. 
collapse sectionIII. 
  
collapse section 
  
  
  
  
  
  
collapse section 
  
  
  
  
  
collapse section 
  
  
  
  
collapse sectionTHREE. 
collapse section 
collapse section 
  
  
  
collapse section 
  
  
  
collapse section 
collapse sectionI. 
  
collapse sectionII. 
  
  
collapse sectionIII. 
  
  
  
collapse section 
  
  
  
collapse section 
  
  
  
collapse section 
  
  
  
collapse section 
  
  
collapse section 
  
  
  
collapse section 
  
  
  
collapse section 
  
  
  
collapse section 
  
  
  
collapse section 
  
  
  
collapse section 
  
  
  
collapse section 
  
collapse section 
  
  
  
collapse section 
  
  
  
collapse section 
  
  
collapse section 
  
  
  
collapse section 
  
  
  
collapse section 
  
collapse section 
  
  
collapse section 
  
  
collapse section 
  
  
  
  
  
  
  
  
  
  
  
  
collapse section 
  
  
collapse section 
  
  
  
  
  
collapse section 
  
  
  
  
  
  
  
collapse section 
collapse section 
  
  
  
  
  
collapse section 
  
collapse section 
  
  
collapse section 
  
  
collapse section 
collapse section 
collapse section 
 100. 
 101. 
 102. 
collapse section 
 103. 
 104. 
 105. 
collapse section 
 200-201-202. 
 203-204. 
 250-251-252. 
 253-254. 
collapse section 
 300-301-302. 
 309-310-311. 
 330-331-332. 
 333-334-335. 
 336-337-338. 
 303-304-305. 
collapse section 
 350-351-352. 
 359-360-361. 
 380-381-382. 
 383-384-385. 
 353-354-355. 
collapse section 
 400-401-402. 
 403-404-405. 
 406-407. 
 420-421-422. 
collapse section 
 450-451-542. 
 453-454-455. 
 45x-456-457. 
collapse section 
collapse section 
 500. 
 501. 
 502. 
collapse section 
 503. 
 504. 
 505. 
collapse section 
 506. 
 507. 
collapse section 
 553. 
 554. 
collapse section 
collapse section 
 600. 
 601. 
  
 650. 
 651. 
 652. 
collapse section 
 603. 
 604. 
 605. 
  
 653. 
 654. 
 655. 
collapse section 
 660. 
 661. 
 662. 
 663. 
 664. 
collapse section 
 700. 
 701. 
 702. 
 703. 
 704. 
 705. 
 706. 
 707. 
 708. 
 750. 
 751. 
 753. 
 755. 
 756. 
collapse section 
 800. 
 801. 
 802. 
 803. 
 804. 
 805. 
 806. 
 807. 
 851-2-3. 
 860. 
collapse section 
 900. 
 901. 
 902. 
 903. 
 904. 
 905. 
 906. 
 907. 
 908. 
 941. 
 950-951-952. 
 953-954-955. 
 956. 
  
  
  
  
  
  
  
  
  
  
  
ELECTRICAL ENGINEERING LABORATORY.
  
collapse section 
collapse section 
  
  
  
collapse section 
  
  
  
  
  
  
  
  
collapse sectionFOUR. 
collapse section 
  
  
collapse section 
  
  
  
  
  
  
  
collapse section 
  
  
collapse section 
  
  
collapse section 
collapse section 
  
  
  
  
  

  
  

ELECTRICAL ENGINEERING LABORATORY.

The Scott Laboratory of Electrical Engineering.—This laboratory was
initially equipped and endowed by Mrs. Frances Branch Scott, of Richmond,
Va., as a memorial to her late son, an alumnus of this university.
During the year 1910 the equipment was substantially increased through
the generosity of the Hon. Charles R. Crane, of Chicago, Ill., a friend of
the university. During 1912, still further substantial additions were made,
consisting of measuring instruments, auxiliary control apparatus, and more
particularly a steam-turbine driven three-phase alternating current generator
with exciter and control switchboard.

In addition to full sets of electric meters with the appliances for testing
and calibrating them, galvanometers of the best modern types, standard
cells and resistances, standard condensers, and other pieces of apparatus for
minor tests, this laboratory contains numerous pieces of the very best
construction. Such are the Wolff Potentiometer, the Siemens and Halske
Thomson Double Bridge, the Koepsel Permeameter, the Duddell Double
Projection Oscillograph, the Station Photometer with Lummer-Brodhum
screen, the Carey-Foster Bridge and others. For the work in machine-testing


226

Page 226
there are a number of direct current generators and motors, series,
shunt and compound, an interpole motor, a double current generator, a
two-phase alternator, a General Electric experimental test set for alternating
current, comprising a generator furnishing single, two, three, six
or twelve-phase current, and, in addition, offering three types of induction
motors with all necessary starting and controlling devices, a single-phase
repulsion motor, a two-phase induction motor, two three-phase induction
motors, several pairs of constant voltage transformers, a constant current
transformer, frequency meters, power factor indicator, synchronism indicator,
ground detector and the auxiliary apparatus used in testing these
machines. The laboratory has been arranged with a system of universal
plug and receptacle-connections to facilitate the setting up of all experimental
combinations.